EL CARRETON #2
400 PEARL NIX PKWY GAINESVILLE, GA 30501
Latest available inspection
Hall CountyWhat the inspector found
All 4 findings ↗4 findings recorded on Oct 14, 2026. 1 marked corrected on site.
Violation recordedItem 15A ↗
Equipment design and condition
Observed gaskets on both cooler drawers under the grill to be in disrepair. Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Inspector’s full note
Inspection item: Food and nonfood-contact surfaces cleanable, properly designed, constructed, and used
Code 511-6-1.05(6)(a)
Observed gaskets on both cooler drawers under the grill to be in disrepair. Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications. CA: PIC to replace or repair gaskets as needed. New Violation. Correct By: 10/24/2026
Official report · Item 15A ↗Correction status not recorded
Correct by
Violation recordedItem 15C ↗
Equipment cleanliness
Observed fan covers on condenser unit in WIC to have accumulation of dust. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
Inspector’s full note
Inspection item: Nonfood-contact surfaces clean
Code 511-6-1.05(7)(d)
Observed fan covers on condenser unit in WIC to have accumulation of dust. Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues. CA: PIC to ensure fan covers are cleaned at a frequency that prevents heavy accumulation. New Violation. Correct By: 10/24/2026
Official report · Item 15C ↗Correction status not recorded
Correct by
Violation recordedItem 16B ↗
Plumbing and drainage
Observed backflow device on mop sink to be leaking while operating. A backflow or backsiphonage prevention device installed on a water supply system shall meet American Society of Sanitary Engineering (A.S.S.E.) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device.
Inspector’s full note
Inspection item: Plumbing installed; proper backflow devices
Code 511-6-1.06(2)(e)
Observed backflow device on mop sink to be leaking while operating. A backflow or backsiphonage prevention device installed on a water supply system shall meet American Society of Sanitary Engineering (A.S.S.E.) standards for construction, installation, maintenance, inspection, and testing for that specific application and type of device. CA: PIC to contact appropriate personnel to service backflow device on mop sink. New Violation. Correct By: 10/17/2026
Official report · Item 16B ↗Correction status not recorded
Correct by
Read 1 more finding
Violation recordedItem 16B ↗
Plumbing and drainage
Observed hand-operated pre-rinse sprayer on the 3-compartment sink to be hanging below the rim of the sink. An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch (25 mm).
Inspector’s full note
Inspection item: Plumbing installed; proper backflow devices
Code 511-6-1.06(2)(d)
Observed hand-operated pre-rinse sprayer on the 3-compartment sink to be hanging below the rim of the sink. An air gap between the water supply inlet and the flood level rim of the plumbing fixture, equipment or nonfood equipment shall be at least twice the diameter of the water supply inlet and may not be less than 1 inch (25 mm). COS: PIC immediately hung-up hand-operated pre-rinse sprayer. Corrected On-Site. New Violation.
Official report · Item 16B ↗Marked corrected on site
Correction status comes from the dated report. Later changes may not be recorded here.
Inspection history 1
Official history ↗- Latest available97/100AReport